NANOSCAN® PET/CT

PET/MRI 1T and SPECT/CT/PET
Real dynamic PET-system designed for quantitative studies
The nanoScan® PET system is equipped with the finest detector crystal needles ensuring high spatial resolution down to 700 μm in vivo.

Quantitative results delivered over the widest range of radioactivity levels from 60 Bq to 60 MBq (1.6 nCi – 1.6 mCi). It covers the full range of PET applications from long-term cell tracking to dynamic studies with 11C- and 15O-labelled radiotracers in rats.

Large ring diameter allows imaging of multiple mice and large animals, while the unique, Tera-Tomo™ 3D iterative reconstruction based on real-time Monte Carlo simulation ensures homogeneous image quality over the entire field of view.
Open access to the animal during PET scanning gives full control over the animal studies.
The PET system is also available in triple-modality combination with our high-end SPECT (nanoScan SPECT/CT/PET) or fully integrated with MRI (nanoScan PET/MRI).

Resolving precise details with 700 μm spatial resolution
Finest lutetium oxyorthosilicate (LSO) crystal needles provide precise signal localization preserving spatial information in raw data
Tera-Tomo™ 3D PET iterative reconstruction with real-time Monte Carlo based physical modelling unveiling the tiniest details on the image
Large ring diameter and statistical depth of interaction compensation offer homogeneous image quality over the entire field of view

Uncompromised applications with very low level of radioactivity
Thick LSO crystals for excellent sensitivity
Advanced corrections (random, scatter, LSO background etc.) ensuring quantification at low activity levels
Best minimal detectable activity on the market: 60 Bq (1.6 nCi)
Inherently optimized for longitudinal studies e.g. long-term cell tracking

Coping with count rate: mastering studies with high dose
Multichannel read-out electronics with ultra-fast data processing and advanced dead-time correction
Exceptional count rate performance – peak noise equivalent count rate (NECR) for mouse is 850 kcps @ 60 MBq
Fully quantitative at 60 MBq (1.6 mCi) and beyond
Suitable for dynamic imaging of large animals or for dynamic scanning of up to four mice simultaneously
Optimal for imaging of isotopes with short half-life (11C, 13N, 15O etc.)

Largest transaxial field of view
Wide bore diameter of 16 cm allowing open access to the animals
Large transaxial field of view of 12 cm
Excellent homogeneity over the entire field of view
Suitable for various animal models from tiny mouse to large rabbits (6.5 kg)
Simultaneous multiple animal imaging (up to 4 mice or 2 rats) with individual physiological monitoring function

High power CT with large field-of-view and high resolution
Up to 80 W X-ray power enables high-performance scanning even for large or multiple animals
Variable magnification for high-resolution imaging with 10 μm isotropic voxel size
Very high throughput: fast scanning with real-time image reconstruction combined with multiple animal imaging capability
Iterative image reconstruction for low-noise and low-dose imaging
Ultra-low-dose protocol for follow-up studies with only 1 mSv whole-body dose to the animal
Imaging with cardiac and respiratory gating